The inductance measuring instrument has a simple and practical sorting function, the parameter setting of this function is simple and easy, and the result display is intuitive, which can meet the requirements of the incoming inspection of people's use units and the rapid sorting measurement of inductance production line. The inductance tester adopts bridge circuit structure, and the standard inductor and the tested inductor are two arms of the bridge circuit. When an inductor's inductance value is measured, the test voltage is applied to both the standard inductor and the inductor under test, and the processor passes through the sensor......
Inductance measuring instrumentIt has a simple and practical sorting function, the parameter setting of this function is simple and easy, and the result display is intuitive, which can meet the requirements of the incoming inspection of the unit and the rapid sorting measurement of the inductance production line. The inductance tester adopts bridge circuit structure, and the standard inductor and the tested inductor are two arms of the bridge circuit. When measuring the inductance value of the inductor, the test voltage is applied to the standard inductor and the inductor under test at the same time, and the processor collects the current signal flowing through both of them through the sensor and processes it to obtain the inductance value of the inductor under test. Yileride focus on inductance measuring instrument and other equipment, support hardware and software development/design/Manufacturing one-stop non-standard customization, adhere to iterative research and development to continuously improve product accuracy and stability.
Due to the synchronous sampling technology of standard inductor and tested inductor, it is not affected by power supply voltage fluctuation; In addition, the measurement process is fully automatic, avoiding the error caused by manual operation, so it has the characteristics of good stability, good repeatability, accurate and reliable.
Features:
1Measurement of single capacitance or total capacitance of parallel and integrated devices without disassembling wires.
2Measure the inductance of the reactor and the wave stopper without disassembling the wire.
3Measure the inlet capacitance of transformer and generator without disassembling the wire.
4, with parallel connection(Electric discharge)Resistance value measurement function
5It can make up for the problem of low fault detection rate caused by low output voltage of capacitor meter.
6Synchronous display of voltage and current waveform and phase, calculate the measured capacitor power loss.
Wiring method:
1Connect one end of the voltage cable to the voltage output terminal;
2The test current signal cable is plugged into the current input plug.
3Connect the capacitor bridge power cable.
4Clamp the test voltage cable respectively on the connection bus of the two poles of the tested capacitor bank, and clamp the clamp meter on the sleeve of the single capacitor that needs to be measured.
Note: Be sure to pass the voltage output red wire through the front of the clamp meter before connecting it to the single capacitor to be measured(Electric reactor)The measurement is not accurate when the casing is reversed.
Eileride focuses on the development of intelligent micro-precision precision parts size measurement equipment, and has served in automotive parts, aerospace, military, bearing, hydraulic valve, robot, automation integration, medical, air conditioning compressor and other fields. In the process of serving customers at home and abroad, Yilerade forged a number of young, knowledgeable, diligent and respectful teams, fully serving customers in the pre-sale technical solution exchange, product quality assurance in the sale, after-sales tracking service to meet customer needs, strength and reputation and advanced!
Model:E-MA4; Measuring range:±25μm,±50μm; Resolution:0.1/0.2/0.5/1.0; Total error:2%; Number of channels:Single; Measuring function:MXMNMNIAN-AMIN2
Model:E-MC5; Measuring range:±25μm,±50μm; Resolution:0.1/0.2/0.5/1.0; Total error:≤0.3μm; Number of channels:Single; Measuring function:MXMNMNIAN-AMIN2
Display screen:7Inch; A/E:EA-2; Accuracy:≤0.3μm Resolution:0.1/0.2/0.5/1.0 Unit:μm/mm/inch