Pneumatic probe and calibrator are indispensable tools in the field of precision measurement, and their accuracy and stability are directly related to product quality and production efficiency. In order to ensure the reliability of the measurement results, it is very important to check the pneumatic probe and calibration gauge regularly. When verifying the pneumatic probe, it is first necessary to check whether its appearance is intact and whether there is obvious damage or wear. The probe is then calibrated using a standard gauge block to ensure that the measured values are consistent with the standard values. In calibration......
Pneumatic probe and calibrator are indispensable tools in the field of precision measurement, and their accuracy and stability are directly related to product quality and production efficiency. In order to ensure the reliability of the measurement results, it is very important to check the pneumatic probe and calibration gauge regularly.
When verifying the pneumatic probe, it is first necessary to check whether its appearance is intact and whether there is obvious damage or wear. The probe is then calibrated using a standard gauge block to ensure that the measured values are consistent with the standard values. In the calibration process, attention should be paid to the operation specification to avoid human error. At the same time, it is also necessary to pay attention to the impact of environmental factors, such as temperature, humidity, etc., which may have an impact on the measurement results.
The verification method of the calibrator is similar to that of the pneumatic probe. First of all, check whether the appearance and identification of the gage are clear and accurate. The calibrator is then calibrated using a measuring tool with known accuracy, such as vernier calipers, micrometers, etc. In the calibration process, it is necessary to carefully observe whether the indicating value of the calibration gauge is consistent with the standard value, if there is a deviation, it is necessary to adjust in time.
In addition, the verification work also needs to pay attention to the following points: First, regular verification to ensure the accuracy and stability of the measurement tool;The second is to standardize the operation to avoid human error;The third is to make good records for easy traceability and analysis.
Through the above verification methods, the accuracy and reliability of the pneumatic probe and proofreading gage can be ensured, and the product quality and production efficiency can be strongly guaranteed.
Model:E-MA4; Measuring range:±25μm,±50μm; Resolution:0.1/0.2/0.5/1.0; Total error:2%; Number of channels:Single; Measuring function:MXMNMNIAN-AMIN2
Model:E-MC5; Measuring range:±25μm,±50μm; Resolution:0.1/0.2/0.5/1.0; Total error:≤0.3μm; Number of channels:Single; Measuring function:MXMNMNIAN-AMIN2
Display screen:7Inch; A/E:EA-2; Accuracy:≤0.3μm Resolution:0.1/0.2/0.5/1.0 Unit:μm/mm/inch