Precision parts size pneumatic measurement equipment manufacturers

Looking forward to provide service for you
hot keywords:
Eccentricity brands
Pneumatic probe price
Gas meter price
Location: Home » News » Technical information » What is the correct way to operate a gas meter?
font: Big Middle Small

What is the correct way to operate a gas meter?

Released Date: Sep 12,2023 Article Source: Elayred
Correct operation of the gas gauge:

    Correct operation of the gas gauge:
    1Power-on check: If the gas meter does not show any indication after power-on, we need to check whether the power connection is normal and the safety tube is normal.
    2Calibration standard parts: If the reading is found to be abnormally unstable in use, and the measured value is large, it may be that the standard parts are not corrected, and the standard parts can work normally after correction.
    3Safe electricity: In order to ensure the normal operation of the gas meter and ensure personal safety, pay attention to the power grounding wire must be grounded, and the power must be cut off before unplugging the power connection plug and opening the shell.
    4Adjust the air pressure: ensure that the air pressure is in0.3~0.7Mpa, usually the pressure is set to0.50MPa. If the air source pressure is less than0.40MPaIts readings will be unstable.
    5Configure the air filter: The air source stage needs to be configured with an air filter.
    6Insufficient power processing: When adjusting the power, if the power knob has been adjusted to the upper limit after the power is still insufficient, it may be that the initial working gap of the probe is too large, you can change to a higher range, if this method is still not available, then the probe will be replaced.
    7Locking power twist: After the power adjustment, be sure to lock the screw to lock the power twist, otherwise it will reduce the stability of the instrument.8Maintenance probe: The gas probe is a loss product, so it needs to be replaced regularly to ensure the measurement accuracy, and regular maintenance is required to apply anti-rust oil.

What is the correct way to operate a gas meter?

    As a precision parts size pneumatic measurement equipment manufacturers, focusing on micro-precision, R & D and production of digital display pneumatic momentum meter, a variety of models, quality assurance, manufacturers direct sales, price concessions.

    If you are Digital display gas momentum meter Interested or want to know more details, please click on our online customer service for consultation, or directly call the national unified service hotline   400-682-7787 . We look forward to hearing from you!

Recommend products

E-MA4 gas momentum meter

E-MA4 gas momentum meter

Model:E-MA4; Measuring range:±25μm,±50μm; Resolution:0.1/0.2/0.5/1.0; Total error:2%; Number of channels:Single; Measuring function:MXMNMNIAN-AMIN2

E-MC5 gas momentum meter

E-MC5 gas momentum meter

Model:E-MC5; Measuring range:±25μm,±50μm; Resolution:0.1/0.2/0.5/1.0; Total error:≤0.3μm; Number of channels:Single; Measuring function:MXMNMNIAN-AMIN2

E-ME7 gas momentum meter

E-ME7 gas momentum meter

Display screen:7Inch; A/E:EA-2; Accuracy:≤0.3μm Resolution:0.1/0.2/0.5/1.0 Unit:μm/mm/inch

联系我们