Does the way of use affect the stability of the gas gauge?

Released Date: May 11,2023 Article Source: Elayred
In order to measure the stability of the air momentum meter, not only the manufacturer must ensure the quality of the air momentum meter manufactured, but also the operator must use the air momentum meter in the correct way:
    In order to measure the stability of the air momentum meter, not only the manufacturer must ensure the quality of the air momentum meter manufactured, but also the operator must use the air momentum meter in the correct way:
    1The environment does not meet the requirements
    The gas meter has high requirements for the use of the environment, so it must meet the environmental requirements when used, if it does not meet the requirements, there will be instability of the gas meter. The operating environment generally requires a temperature of10~40℃, the ambient humidity is40%Below, the surrounding environment requirements must be kept clean, no corrosive dust, etc.
    2The foundation stability is not good
    The foundation has a direct impact on the stability, because if the foundation has vibration, it will cause the vibration of the whole instrument, and the measurement stability will be reduced at high magnification, so it should be away from the vibration source. Some instruments with particularly high accuracy should also be used in the vibration shelter in the basement.
    3Improper personnel operation

    The correct use of the gas gauge is the key to ensure the success of each measurement. The measurement requires that the measuring force of the parts with higher accuracy be placed very small, otherwise it will be too large, and in fact cause a force to be added to the parts under test, making the parts under test move a little when rotating, resulting in different data measured each time, the surface looks like the stability of the instrument is poor, in fact, it is caused by improper use by the user.

Does the way of use affect the stability of the gas gauge?

    As a precision parts size pneumatic measurement equipment manufacturers, focusing on micro-precision, R & D and production of digital display pneumatic momentum meter, a variety of models, quality assurance, manufacturers direct sales, price concessions.
    If you are Digital display gas momentum meter Interested or want to know more details, please click on our online customer service for consultation, or directly call the national unified service hotline 400-682-7787. We look forward to hearing from you!

Recommend products

E-MA4 gas momentum meter

E-MA4 gas momentum meter

Model:E-MA4; Measuring range:±25μm,±50μm; Resolution:0.1/0.2/0.5/1.0; Total error:2%; Number of channels:Single; Measuring function:MXMNMNIAN-AMIN2

E-MC5 gas momentum meter

E-MC5 gas momentum meter

Model:E-MC5; Measuring range:±25μm,±50μm; Resolution:0.1/0.2/0.5/1.0; Total error:≤0.3μm; Number of channels:Single; Measuring function:MXMNMNIAN-AMIN2

E-ME7 gas momentum meter

E-ME7 gas momentum meter

Display screen:7Inch; A/E:EA-2; Accuracy:≤0.3μm Resolution:0.1/0.2/0.5/1.0 Unit:μm/mm/inch

联系我们